BD Accuri™ C6 Plus Personal Flow Cytometer

The cell analyzer with capabilities to bring flow cytometry even more within reach for new and experienced researchers alike

Overview

The BD Accuri™ C6 Plus Flow Cytometer, with its compact 11 x 14.75 x 16.5-inch footprint, light weight of 30 lb and operational simplicity, supports a wide variety of applications including immunology, cell and cancer biology, plant and microbiology and industrial applications. This portable and compact cell analyzer holds the analytical power of a cytometer twice its size. Used in thousands of research studies, the BD Accuri™ C6 Plus System provides an easy-to-use option to your research toolbox.

 

Get kits and templates for the BD Accuri C6 Plus Personal Flow Cytometer (also work with the discontinued BD Accuri C6 Personal Flow Cytometer).

 
performance1

Features

The BD Accuri™ C6 Plus Cell Analyzer Provides Simplicity and Sensitivity on Your Benchtop 

 

Optics

  • Equipped with a blue and red laser, two light scatter detectors and four fluorescence detectors with optical filters optimized for the detection of many popular fluorochromes, including FITC, PE, PerCP-Cy5.5 and APC
  • Easy to use with no need to adjust detector voltage
  • Data are digitally collected over a wide dynamic range and are fully available to you as needed, eliminating the risk of data loss due to incorrect settings
  • Software functions such as Zoom and VirtualGain allow visualization of data at any scale, so you can precisely set gates and regions
  • Extraordinary fluorescence sensitivity with optical and fluidic design provide the ability to withstand rugged conditions. Provided the system is anchored, it can run samples even if the benchtop is in motion, such as aboard a ship

 

Find out about BD Accuri™ C6 Plus System fluorochrome support.

Excitation Wavelength Fluorochromes/Dyes Standard Filter Optional Filter
488 nm FITC, BB515, Alexa Fluor™ 488, CFSE 533/30 -
GFP 533/30 510/15
JC-1, Fluo-4 AM, SYBR™Green  533/30 -
YFP  533/30 540/20
PE, JC-1, BD™ MitoStatus TMRE  585/40 -
OFP  585/40 565/20
Propidium Iodide  585/40, 670 LP 610/20
BD Horizon™ PE-CF594  670 LP 670 LP>610/20
RFP, mCherry, dsRed  670 LP 610/20
PerCP, PE-Cy5  670 LP -
PerCP-Cy5.5  670 LP 670 LP>-
7-AAD  670 LP 670 LP>780/60
PE Cy7  670 LP 780/60
640 nm APC, BD™ MitoStatus Red, Alexa Fluor™ 647 675/25 LP -
APC-H7, APC-Cy7  670 LP 780/60

 

 

Performance

Adaptable optics, with many filter, laser and configuration options, and the unique fluidics system provide flexibility in the fluorochrome combinations you can analyze and automation for direct counting of cells

Applications

BD Accuri™ C6 Plus Personal Flow Cytometer

The cell analyzer with capabilities to bring flow cytometry even more within reach for new and experienced researchers alike

Request a Quote
performance1
Resources and Training
Expand All Collapse All

For Research Use Only. Not for use in diagnostic or therapeutic procedures.

Class 1 Laser Product.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.

Class 1 Laser Product.

All reagents and kits are compatible with both the BD Accuri C6 Plus and BD Accuri C6 Flow Cytometer Systems. Platforms referred to as "BD Accuri" represent both the BD Accuri C6 Plus and BD Accuri C6. Data were generated on either the BD Accuri C6 Plus or the BD Accuri C6 System as indicated in figure legends.

BD Accuri C6 System (32-bit) Software is not forward compatible with BD Accuri C6 Plus (64-bit) Software and the FCS 3.1 file format.

Alexa Fluor is a trademark of Life Technologies Corporation. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva. Dell and OptiPlex are trademarks of Dell Inc. Microsoft and Excel are trademarks of Microsoft Corporation. SYBR is a trademark of Thermo Fisher Scientific.